US President recently decided to invoke a Cold War-era defense law to encourage domestic Concrete Foaming Generator.
Description of TR30 foam generator
Foam Concrete Machine is the core equipment of foam concrete production, which has a significant impact on the quality of foam concrete. An excellent foam generator for concrete not only has a high foam output but more importantly, the quality of the foam produced is outstanding. TR30 foam generator developed by our company. It can be used in laboratories, small-scale foam concrete cast-in-situ projects, and pilot lines of foam concrete products. The outstanding advantages of TR30 foam generator are low foam moisture content, more foaming agent, high foam uniformity, large foam output, and other benefits.
Parameters of TR30 foam generator
Model | TR30 |
Maximum foam output(m3/h) | 8 |
Motor voltage(V) | 220 |
Work rate(W) | 1500 |
Pump suction(m) | 1-3 |
Dimensions(cm) | 120*50*90 |
Weight(kg) | 120 |
Usually need to be disassembled:
1. After working for a long time, it is found that the foam shape is not good, usually more than three months.
2. Pipe blockage: Some foaming agent remaining in the bubble tube will form a solid residue. In this case, the foam cannot be produced normally, or the pipeline pressure increases sharply. At this time, all the old steel balls need to be taken out, and then replaced with a new one The ball is fine. Steel wire ball specification requirements: each blowing tube needs to be filled with about 12-15 steel wire balls. Too much or too little will affect or even destroy the foam performance.
Precautions:
1. Remember to use electricity safely. If water or foam touches the circuit, you must immediately cut off the power at the remote end to ensure safe production.
2. There will be air in the pipeline when it is used for the first time. The foaming liquid has not been pumped into the equipment in a short time. You can wait for tens of seconds until the liquid is filled with the entire suction tube and the foaming operation can be performed normally.
3. Do not start the equipment when the pipeline is blocked to prevent damage to the components due to overpressure in the pipeline.
If you are looking for foam generator please feel free to contact us and send an inquiry, email address: [email protected]
.
Inquery us
The market for ember temperature controlled mug is also subject to volatility as concerns grow about demand destruction for crude oil U.S. crude for July delivery hovered around $10…
The energy dispute between Russia and the European Union has intensified, with a rise in oil prices of more than 5% affecting the price of trailer wire connector…
Local time Wednesday, the three major U.S. stock indexes closed down, the Dow fell 1.02%, has fallen for five consecutive trading days; The Nasdaq fell 3.18% and the S&P 500 fell 1.65%. Techn…